BP117142 - 103 - 1930 Island Diesel Way -- Scanned
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP117142 - 103 - 1930 Island Diesel Way -- Scanned | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 103 - 1930 Island Diesel Way -- Scanned |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP117142 |
Date Application Submitted: | March 21, 2012 |
Application Description: |
Ahaus Const. Warehouse. 130m2 Complete and occupy work includes finishing concrete floor and installing a universal washroom with one new sprinkler head and completing the 3/4 hr demising wall between suites. Part 9, F2 (Industrial) 390.2m2, 2 storey building, fire alarm, sprinklered, combustible construction permitted with exception of exterior South wall which has a non-combustible 2 hr FRR for spatial separation. 3/4 hr ceilings throughout as part of suite separation. Building has 3 strata units. September 10th, 2012 - Plans revised to include an unfinished 2nd floor level. |
Application Status: | COMPLETED |
Permit Value: | $14,000.00 |
Issued Date: | April 04, 2012 |
File Close Date: | April 02, 2013 |
Associated Properties
Address | Zone | More |
---|---|---|
103 1930 ISLAND DIESEL WAY | I3 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2013-04-02 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.