BP118639 - 1451 Estevan Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP118639 - 1451 Estevan Road | |
---|---|
Neighbourhood: | Newcastle/Brechin |
Street Address: | 1451 Estevan Road |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP118639 |
Date Application Submitted: | May 27, 2013 |
Application Description: |
New 3 storey office building for VIHA Shell building and Related site works. Building Description, Part 3, Governing article 3.2.2.2.59 BCBC 2012. Combustible or non combustible construction permitted non combustible provided. Floor assemblies FS with 0Hr FRR, 1hr Provided. Loadbearing walls comlumns and arches required to be non combustible no rating required 1hr provided. Vertical service spaces FS no FRR required . Elevator hoistway to be a FSwith a 45min FRR. Elevator service room FS with 45min FRR. Service rooms consturcted as FS with 1Hr FRR. South exposed building face with 6.3m L.D.(for future building) Requires 45min FRR. East exposed building face requires Non combustible construction and non combustible cladding and 1Hr FRR. Building sprinkled with fire alarm. Building Area by code 380.37m2. First storey group D floor area 331.59m2. Second storey group D 333.45m2. Third storey group D 333.45m3 |
Application Status: | COMPLETED |
Permit Value: | $1,200,000.00 |
Issued Date: | October 04, 2013 |
File Close Date: | October 31, 2014 |
Expiry Date: | October 04, 2015 |
Associated Properties
Address | Zone | More |
---|---|---|
1451 ESTEVAN ROAD | CC3 | Property Report |
Process Steps
Task | Status |
---|---|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
SCHEDULED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
STORM CONNECTION
Pipe and connection must be visible for inspection. |
CANCELLED |
SANITARY CONNECTION
Pipe and connection must be visible for inspection. |
CANCELLED |
WATER CONNECTION
Pipe and connection must be visible for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
OCCUPANCY-OLD |
PASSED
2014-10-31 |
FINAL-OLD
Final approval as per requirements on plans. |
CANCELLED |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.