BP118857 - 2052 Boxwood
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP118857 - 2052 Boxwood | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 2052 Boxwood |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP118857 |
Date Application Submitted: | August 16, 2013 |
Application Description: |
Industrial Plastics and Paints (xreference BP118867 for foundation permit) Part 3 Building , 2 Storeys, Sprinklered, Fire Alarm System, 1st storey, Industrial (Group F2) occupancies. Subsidiary Retail sales and display (200m2 located on plan < 25%) , 2nd Storey, Industrial (Group F2) Storage. 1st Storey = 872.8 m2, 2nd Storey = 179.6 m2, Construction Article 3.2.2.77, 45 min. FRR/FS for floor assembly and 45 min. for load-bearing supports if combustible and 45 min. FRR/FS for 2nd storey wall separation and 45 min. for the exit enclosure. |
Application Status: | COMPLETED |
Permit Value: | $737,600.00 |
Builder: | MIKON CONSTRUCTION LTD |
Issued Date: | October 11, 2013 |
File Close Date: | April 24, 2014 |
Process Steps
Task | Status |
---|---|
SANITARY CONNECTION
Pipe and connection must be visible for inspection. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
FAILED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
OCCUPANCY-OLD | FAILED |
OCCUPANCY-OLD |
PASSED
2014-04-24 |
FINAL-OLD
Final approval as per requirements on plans. |
CANCELLED |
FINAL-OLD
Final approval as per requirements on plans. |
PARTIAL |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2014-04-24 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.