BP121555 - 477 B Wallace Street
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP121555 - 477 B Wallace Street | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 477 B Wallace Street |
Type of Application: | Leasehold Improvements |
File Number: | BP121555 |
Date Application Submitted: | December 31, 2015 |
Application Description: |
Adding accessible washroom, unisex washroom and sink, remove existing wall, infill existing ramp, changing entry door and completing GWB. Future Permit required for tenant improvement. Building Classification BCBC 2006: 3.2.2.59. Group E occupancy, Existing 360m2 (approx), three storey, combustible construction, unsprinklered, 3/4 hr FS for floor assemblies, retail /office building with historic non-conforming assembly use on main floor. Existing FS between office floors unknown. |
Application Status: | RETIRED |
Permit Value: | $18,208.79 |
Issued Date: | February 15, 2016 |
File Close Date: | August 16, 2024 |
Expiry Date: | February 14, 2018 |
Associated Properties
Address | Zone | More |
---|---|---|
477 WALLACE STREET | DT7 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
FAILED |
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
FAILED |
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.