BP122670 - 1930 Boxwood Road (BLDG 1)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP122670 - 1930 Boxwood Road (BLDG 1) | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 1930 Boxwood Road (BLDG 1) |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP122670 |
Date Application Submitted: | November 09, 2016 |
Application Description: |
Construction of an Industrial warehouse and shell office space, part 9 building, floors require a 45min FRR (although 1hr provided) and a 1hr FRR between the F2 and D occupancies. Service room has a 45min FRR wall. Sprinklered by By-Law, fire alarm system not required. Total building area is 377.8m2 with the first floor warehouse at 253.3m2 and the second storey office at 125.5m2. South wall setback 0.3m from property line and front yard setback of 4.5m. South wall constructed as a 2hr FRR concrete wall assembly. REVISION: Sept 24/20 -revision to sprinklers as per Des Design as-built REVISION: Oct 4/19- Construction of interior partition walls for reception area, offices, washrooms, staff areas, etc. Relocation & Addition of Emergency lighting, Exit signage, Fire Alarm pull stations & bells. Relocation of Sprinkler Heads. Addition of 5 handwash sinks, 2 pc washrooms with shower. REVISION: June 12, 2020 - Revise back to shell building with 2 R/I washrooms and second floor. |
Application Status: | COMPLETED |
Permit Value: | $560,000.00 |
Builder: | DOGWOOD MOUNTAIN HOMES LTD |
Issued Date: | January 12, 2017 |
File Close Date: | October 20, 2020 |
Expiry Date: | November 09, 2020 |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
CANCELLED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PARTIAL |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
APPROVAL-FIRE-OLD
Approval required prior to Occupancy |
COMPLETED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2020-10-20 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.