BP123990 - 101 - 104 5160 Dublin Way
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP123990 - 101 - 104 5160 Dublin Way | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 101 - 104 5160 Dublin Way |
Type of Application: | Leasehold Improvements |
File Number: | BP123990 |
Date Application Submitted: | December 28, 2017 |
Application Description: |
Tenant Improvement to unit 103 (new Central Drugs Pharmacy) Group E Occupancy and upgrades in units 101-104 to provide 45 minute FRR to all columns. Unit 103 is 173.1m2, one universal toilet room (existing), 1 hour fire separations provided between unit 103 and adjacent tenants, 2 hour fire separation to parking garage below, Work also includes new fire rated interconnecting doors through non-structural fire separation wall to adjacent unit 104 (medical office) on magnetic hold open devices connected to fire alarm system and three new sinks. Existing Building Classification - Group D, 3.2.2.61 facing 1 street, 2 Storey, sprinklered, 1hr FRR between suites, service room separated with 1hr FRR in walls and floor, suspended slab over (parking) storage garage 2 hr FRR required, 45min FRR wall assembly around elevator. Building reclassified under this permit to Group E, 3.2.2.67. which requires 45 minute FRR (min) upgrading of the columns. |
Application Status: | COMPLETED |
Permit Value: | $150,000.00 |
Builder: | R.W. (BOB) WALL LTD. |
Issued Date: | March 23, 2018 |
File Close Date: | May 16, 2018 |
Expiry Date: | March 23, 2020 |
Associated Properties
Address | Zone | More |
---|---|---|
101 5160 DUBLIN WAY | CD5 | Property Report |
102 5160 DUBLIN WAY | CD5 | Property Report |
103 5160 DUBLIN WAY | CD5 | Property Report |
104 5160 DUBLIN WAY | CD5 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
CANCELLED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
OCCUPANCY-OLD |
PASSED
2018-05-16 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.