BP124100 - C - 5107 Somerset Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124100 - C - 5107 Somerset Drive | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | C - 5107 Somerset Drive |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP124100 |
Date Application Submitted: | February 02, 2018 |
Application Description: |
(Sorensen Trilogy) Tenant Improvement to existing Unit "C". Addition of 30 m2 of office space to increase total area to 226 m2, Group D occupancy. Existing F/S has 45 min. FRR and existing 2 hr fire separation between C and D occupancies (3.1.3.1). Remove and relocate interior partition office walls. Install plumbing for staff sink and auto washer. Maximum occupant load of 24 persons. Building reclassified: Main floor (744 m2) - Group D 3.2.2.61. under BCBC 2012; 2nd floor (409 m2) - Group C 3.2.2.53. under BCBC 2012, Existing 2 hr. fire separation between C and D occupancies (3.1.3.1), 2 storey, combustible or non-combustible construction, sprinklered with Fire Alarm system. |
Application Status: | COMPLETED |
Permit Value: | $120,000.00 |
Builder: | SHINING KNIGHT CONSTRUCTION INC |
Issued Date: | May 14, 2018 |
File Close Date: | June 29, 2018 |
Expiry Date: | May 14, 2020 |
Associated Properties
Address | Zone | More |
---|---|---|
5107 SOMERSET DRIVE | COR3 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
FINAL-OLD
Final approval as per requirements on plans. |
CANCELLED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2018-06-29 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.