BP124356 - 108 - 6461 Metral Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124356 - 108 - 6461 Metral Drive | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 108 - 6461 Metral Drive |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP124356 |
Date Application Submitted: | April 24, 2018 |
Application Description: |
Alteration to building classification from Group E to include Group A2 and E Occupancies. Combine units 108, 109 & 110 (Planet Fitness gym), A-2 assembly occupancy 1615m2. Scope of work includes interior walls, mill-work, closing off exterior doors at front and side and walling over two rear exit doors, extensive sprinkler changes, showers, toilets and washbasins in men's and women's change rooms including "accessible" facilities, "universal" toilet room, drinking fountains and service rooms. Building Area 3260 m2, single storey, A-2, and E major occupancies Reclassified BCBC 2012 3.2.2.26. Group A2 & Group E, 3.2.2.65., combustible or non-combustible construction, sprinklered with fire alarm system. Floor assemblies require 3/4 hr FRR. Mezzanines, loadbearing walls and columns require 3/4 hr FRR if of combustible construction. Loadbearing walls, columns & arches supporting a fire separation with a FRR shall have a FRR not less than the required for the FS. |
Application Status: | COMPLETED |
Permit Value: | $900,000.00 |
Builder: | KOR-ALTA CONSTRUCTION LTD |
Issued Date: | September 04, 2018 |
File Close Date: | December 06, 2018 |
Expiry Date: | September 04, 2020 |
Associated Properties
Address | Zone | More |
---|---|---|
6461 METRAL DRIVE | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
APPROVAL-FIRE-OLD
Approval required prior to Occupancy |
PENDING |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2018-12-06 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.