BP124973 - 10 - 1850 Northfield Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124973 - 10 - 1850 Northfield Road | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 10 - 1850 Northfield Road |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP124973 |
Date Application Submitted: | November 09, 2018 |
Application Description: |
Construct new 38.4m2 open mezzanine and stairs in existing unit #10 for (Mazzei Electric), F-2 occupancy with subsidiary offices. Work includes changing 18.5m2 of existing enclosed mezzanine to an open mezzanine, addition of open mezzanine with no required fire resistance rating, sprinkler changes. New total open mezzanines area 59.9m2, enclosed mezzanine area 21.6m2. Building Classification 2012: 983m2, Group F-2, 3.2.2.77. 2 storey, sprinklered with fire alarm, < 1800m2, combustible construction, 45min. FS/FRR for floors if combustible. 4 hr firewall between strata units 5 & 6; west end 517m2, east end 983m2. REVISION: change of stair layout from new mezzanine. April 17, 2019 VS |
Application Status: | COMPLETED |
Permit Value: | $20,000.00 |
Building Area: |
38.40 M2 413.33 ft2 |
Builder: | TECTONICA MANAGEMENT INC |
Issued Date: | March 07, 2019 |
File Close Date: | April 24, 2019 |
Expiry Date: | March 08, 2021 |
Associated Properties
Address | Zone | More |
---|---|---|
10 1850 NORTHFIELD ROAD | I3 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
FINAL-OLD
Final approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2019-04-24 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.