BP125096 - 1200 Dufferin Crescent (MRI addition)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP125096 - 1200 Dufferin Crescent (MRI addition) | |
---|---|
Neighbourhood: | Townsite |
Street Address: | 1200 Dufferin Crescent (MRI addition) |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP125096 |
Date Application Submitted: | December 07, 2018 |
Application Description: |
Construction of an MRI addition and ancillary spaces, (NRGH), Acute Care Hospital, B-2 occupancy, 99.8m2 additional area. Work includes moving existing link corridor and addition of interior space where existing outdoor courtyards are. Courtyards are reduced in size. To re-establish a 1 hr fire compartment at MRI area a rated double swing door on mag-hold will be added, some new walls have a 2 hr FRR. Addition of 2 sinks, MRI rooms, new corridor. 2 hr fire resistance rating required for floor and supports. Alternative Solution water curtain at windows in link corridor & MRI room for exit exposure protection by Celerity. Revision: July2019 CRP & Architect changed. Dec. 2019 Revision: Fire Suppression Eng changed. Building Classification : BCBC2012 - 3.2.2.38 /3.2.6, non combustible construction, sprinklered with fire alarm. Major occupancy B-2 with subsidiary occupancies. Existing Alternative Solution for exit exposure & heavy timber by GBA Aug 12, 2010 |
Application Status: | ACTIVE |
Permit Value: | $2,380,000.00 |
Issued Date: | June 20, 2019 |
Expiry Date: | June 21, 2021 |
Associated Properties
Address | Zone | More |
---|---|---|
1200 DUFFERIN CRESCENT | CS1 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
MONITORED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
APPROVAL-FIRE
Approval required prior to Occupancy |
APPROVED |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.