BP125776 - Unit 111 - 1925 Boxwood Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP125776 - Unit 111 - 1925 Boxwood Road | |
---|---|
Neighbourhood: | Northfield |
Street Address: | Unit 111 - 1925 Boxwood Road |
Type of Application: | Leasehold Improvements |
File Number: | BP125776 |
Date Application Submitted: | August 21, 2019 |
Application Description: |
(Coral Canada Wide Ltd) Canadian HVAC company. Leasehold improvement - Unit 111, 185 m2 of F2 warehouse space with subsidiary office use(Group D). Work includes; completing one universal washroom; one staff washroom; Interior partition walls creating 2 offices and a subsidiary show room/reception area; and kitchenette nook. 1 Hr fire separation provided to adjacent suite with base building permit. Under slab plumbing reviewed with base building permit. Building Classification: 2012 BCBC, 3.2.2.75., Building area is 2234 m2, combustible or non-combustible construction permitted, building is sprinklered with fire alarm system, loadbearing walls, columns and arches supporting a rated assembly shall have a FRR not less than the supported element 45 min. Original BP123885 |
Application Status: | COMPLETED |
Permit Value: | $100,000.00 |
Issued Date: | December 30, 2019 |
File Close Date: | March 20, 2020 |
Expiry Date: | December 29, 2021 |
Associated Properties
Address | Zone | More |
---|---|---|
1925 BOXWOOD ROAD | I2 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
OCCUPANCY-OLD | FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2020-03-20 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.