BP125961 - B - 6683 Mary Ellen Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP125961 - B - 6683 Mary Ellen Drive | |
---|---|
Neighbourhood: | Dover |
Street Address: | B - 6683 Mary Ellen Drive |
Type of Application: | Leasehold Improvements |
File Number: | BP125961 |
Date Application Submitted: | November 08, 2019 |
Application Description: |
(BC Liquor Distribution Branch - BC Cannabis Store #7041) Leasehold Improvement- Unit B - 250.7m2 Work includes changing storefront to create an entry and exist vestibule. Interior renovations to create a secured storage area, managers office, staff room, and sales area. Plumbing work includes adding 2 sinks and relocating HWT. Sprinkler changes include adding 30 new sprinkler heads and changing Design Area. 2 Hr FS/FRR provided between adjacent E and D occupancies. Original Building constructed April 2000, Part 3, Building reclassified Group E, 492 m2 one storey combustible or noncombustible construction. Building sprinklered by bylaw. No rating required for the roof. No ratings required for exterior wall faces. |
Application Status: | COMPLETED |
Permit Value: | $650,000.00 |
Issued Date: | April 24, 2020 |
File Close Date: | July 28, 2020 |
Expiry Date: | April 25, 2022 |
Associated Properties
Address | Zone | More |
---|---|---|
6675 MARY ELLEN DRIVE | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PAPER/FLASHING/WATERPROOFING | PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL
Final Approval as per requirements on plans. |
PASSED
2020-07-28 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.