BP127370 - 230 - 238 Franklyn Street(Mambo pizza)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP127370 - 230 - 238 Franklyn Street(Mambo pizza) | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 230 - 238 Franklyn Street(Mambo pizza) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP127370 |
Date Application Submitted: | March 17, 2021 |
Application Description: |
Complete and occupy (Mambo Gourmet Pizza Ltd.) CRU # 230 - Classified as low occupancy A2 - Group D occupancy, 115m2. Work includes installing a walk in cooler and commercial kitchen. Interior partition walls to create a take out area and commercial kitchen and universal WC. Plumbing work includes addition of 8 sinks, 1 Washbasin,1 Toilet and 1 HWT. Sprinkler Work includes 10 additional heads in the original design area. Exhaust chase on exterior of building built with duct work wrapped for 2 hr FRR to NFPA standard for potential future installation of a NFPA 96 kitchen hood fan. Building classification: 2012 BCBC - Occupancies 3.2.2.50 Groups C, 3.2.2.56 D, 3.2.2.62 E & 3.2.2.80 F2 2022-MAY-17 REVISION: Add Structural Engineers' Schedule B for overheight walls. |
Application Status: | COMPLETED |
Permit Value: | $85,000.00 |
Builder: | TECTONICA MANAGEMENT INC |
Issued Date: | November 01, 2021 |
File Close Date: | September 28, 2022 |
Expiry Date: | November 01, 2023 |
Associated Properties
Address | Zone | More |
---|---|---|
238 FRANKLYN STREET | DT2 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
FAILED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
APPROVAL-FIRE
Approval required prior to Occupancy |
APPROVED |
APPROVAL-VIHA
Approval required prior to Occupancy |
APPROVED |
OCCUPANCY | CANCELLED |
OCCUPANCY | CANCELLED |
OCCUPANCY | FAILED |
OCCUPANCY |
PASSED
2022-09-28 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.