BP128365 - 1619 Townsite Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP128365 - 1619 Townsite Road
Neighbourhood: Northfield    
Street Address: 1619 Townsite Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP128365
Date Application Submitted: March 24, 2022
Application Description: Permit for Change of Use from D/F2 to C/D building, and to resolve CIB05343 for non permitted construction on lower floor. Create new Group C dwelling unit (Unit 202) on upper floor with additional 23.1 m2 GFA, two new Group D CRUs (Units 102, 103) in basement including increased ceiling height and finish previous crawlspace storage area. BCBC 2018 accessible washrooms for new CRUs. Building structure revised to comply with BCBC 2018 Part 9 braced wall band provisions.

Building Reclassification: BCBC 2018 Part 9 Group C/D, 184.1 m2 building area, two storeys, combustible and noncombustible construction, unsprinklered, without fire alarm. 45-min FRR/FS floors, 1-hr FRR/FS between Group C/D occupancies, 45-min FRR/FS (none req'd) between Group D suites. 1-hr FRR/FS service room. 50 STC assemblies separating dwelling unit. Single exits permitted for each CRU, max 10 occupants based on BCBC 3.7.

REVISION: 2025-JAN-28: Layout change to Unit 103, 102, 202. Braced wall panel revision.
Application Status: ACTIVE
Permit Value: $96,000.00
Issued Date: September 09, 2024
Expiry Date: September 09, 2026

Associated Properties

Address Zone More
1619 TOWNSITE ROAD COR3 Property Report

Process Steps

Task Status
EXCAVATION

Excavation of soil, prior to placing forms

CANCELLED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.