BP128453 - 4900 Island Highway (Building A - Subaru) (Alias address 4900 Wills Road)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP128453 - 4900 Island Highway (Building A - Subaru) (Alias address 4900 Wills Road)
Neighbourhood: Rutherford    
Street Address: 4900 Island Highway (Building A - Subaru) (Alias address 4900 Wills Road)
Type of Application: Commercial / Multi / Industrial
File Number: BP128453
Date Application Submitted: May 07, 2022
Application Description: Phase 1, Building A - Subaru Service and Sales. New construction of 2018 BCBC 2 Storey, Part 3 Bldg. Major building classifications 3.2.2.79 (Group F2) repair garage and 3.2.2.86 (Group F3) salesroom/office. Building area 1395m2. Combustible or non-combustible construction, Sprinklered to NFPA13 with Fire Alarm System. Minimum 45min FRR/FS or 0hr FRR/FS non-combustible construction required for floor assemblies and supporting structures. Minimum 2hr FRR/FS between repair garage and all other occupancies. Minimum 45min FRR/FS for exits. Total GFA is 1802.11m2. Total mechanical mezzanines floor area is 39.44m2.

Exposing Bldg face requirements; 1hr FRR with NC cladding for North and East exterior walls (repair garage F2 only).

2024-JUL-18 REVISION: Changes to canopy, canopy drain and underslab plumbing layout.
2024-JUL-25 REVISION: Changes to sprinkler layout, add sink and dw to lounge.
Application Status: ACTIVE
Permit Value: $6,241,440.00
Builder: SUPERB CONSTRUCTION LTD
Issued Date: September 05, 2023
Expiry Date: September 05, 2025

Associated Properties

Address Zone More
4900 ISLAND HIGHWAY N COR3 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PARTIAL
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

MONITORED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy