BP128831 - 6985 Island Highway North - Building A (Alias 6981 Isl Hwy) Main permit
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP128831 - 6985 Island Highway North - Building A (Alias 6981 Isl Hwy) Main permit | |
---|---|
Neighbourhood: | Dover |
Street Address: | 6985 Island Highway North - Building A (Alias 6981 Isl Hwy) Main permit |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP128831 |
Date Application Submitted: | October 24, 2022 |
Application Description: |
New construction of 5 storey, 75 unit apartment building with underground parking. Building Classification: Group C 3.2.2.50, including underground parking Group F3 3.2.2.82. 1161.4 m2 Building Area, combustible, sprinklered with fire alarm system. Key FRR/FS: 1hr FRR/FS 50 STC between suites and suites /corridor and exit stairs 1hr FRR/FS 55 STC between suites/elevator shaft, 1hr FRR/FS for floor/roof assemblies and supporting elements, storage end electrical rooms. 1.5 hr fire FRR/FS between parking garage and other occupancies. All doors in fire separations to be self-closing with positive latching mechanisms. Total GFA is 6,989.45 m2. |
Application Status: | ACTIVE |
Builder: | WINDLEY CONTRACTING LTD |
Issued Date: | November 29, 2023 |
Expiry Date: | November 29, 2025 |
Associated Properties
Address | Zone | More |
---|---|---|
6985 ISLAND HIGHWAY N | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.