BP129281 - 619 Comox Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP129281 - 619 Comox Road
Neighbourhood: Downtown/Old City    
Street Address: 619 Comox Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP129281
Date Application Submitted: June 09, 2023
Application Description: Building envelope upgrade and interior renovations to apartment building. Interior renovations include; replacement of plumbing fixtures within suites, and emergency/exit lighting; and upgrades to mechanical/fire alarm systems. Permit includes the new installation of 7 HWTs in basement, and NFPA13/14 sprinkler/standpipe system by bylaw. New interior finishes in suites (floors/bathroom ceilings) and corridors (floors/ceilings). Existing FS/FRR to be maintained.

Existing building classification; Existing NBC 1970 Part 3, 3.2.2.27 Group C (residential), 5 storey with service basement, ~1005m2 building area, unsprinklered (except basement/standpipes/hoses) with fire alarm system. 75 residential suites, 1 office, 1 common solarium. Key FS/FRR include; 2hr FS/FRR floor over basement, 1hr FS/FRR for other floors, between suites, and public corridors, 1hr FRR for supporting structures/balconies/roof, 3/4hr FS/FRR for vertical service spaces.

REVISION 2025-JAN-10: See internal notes
Application Status: ACTIVE
Permit Value: $7,842,545.00
Builder: SAYWELL CONTRACTING LTD
Issued Date: March 13, 2024
Expiry Date: March 13, 2026

Associated Properties

Address Zone More
619 COMOX ROAD DT8 Property Report

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

MONITORED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.