BP129281 - 619 Comox Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129281 - 619 Comox Road | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 619 Comox Road |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP129281 |
Date Application Submitted: | June 09, 2023 |
Application Description: |
Building envelope upgrade and interior renovations to apartment building. Interior renovations include; replacement of plumbing fixtures within suites, and emergency/exit lighting; and upgrades to mechanical/fire alarm systems. Permit includes the new installation of 7 HWTs in basement, and NFPA13/14 sprinkler/standpipe system by bylaw. New interior finishes in suites (floors/bathroom ceilings) and corridors (floors/ceilings). Existing FS/FRR to be maintained. Existing building classification; Existing NBC 1970 Part 3, 3.2.2.27 Group C (residential), 5 storey with service basement, ~1005m2 building area, unsprinklered (except basement/standpipes/hoses) with fire alarm system. 75 residential suites, 1 office, 1 common solarium. Key FS/FRR include; 2hr FS/FRR floor over basement, 1hr FS/FRR for other floors, between suites, and public corridors, 1hr FRR for supporting structures/balconies/roof, 3/4hr FS/FRR for vertical service spaces. REVISION 2025-JAN-10: See internal notes |
Application Status: | ACTIVE |
Permit Value: | $7,842,545.00 |
Builder: | SAYWELL CONTRACTING LTD |
Issued Date: | March 13, 2024 |
Expiry Date: | March 13, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
619 COMOX ROAD | DT8 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
MONITORED |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.