BP129563 - 340 Campbell Street
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129563 - 340 Campbell Street | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 340 Campbell Street |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP129563 |
Date Application Submitted: | September 20, 2023 |
Application Description: |
New construction of a 6 storey 162 unit rental apartment building with a 2 level parkade. Building classification: First floor non-combustible Group C 3.2.2.48 with Group F3 3.2.1.2. Parkade, Building area 3,202.21 m2. 2nd to 6th Floor combustible Group C 3.2.2.50 North-wing building area 991.46 m2, South wing building area 1076.05 m2 separated by a 2hr firewall. Sprinklered with Fire Alarm. Key F/S: 2hr FRR/FS between parkade and residential, 1.5hr FRR/FS between parkade and other occupancies, 1hr FRR/FS-62 STC between units, 1hr FRR/FS-61 STC at elevator shaft, 1hr FRR/FS-52 STC at corridors. Alternative Solutions for Building Classification to address building height and building area by way of a horizontal 2 hr F/S acting as a firewall type construction and for Exit Exposure Protection by way of Water Curtain Sprinkler protection at unprotected openings at building exits. Total GFA: 15799.42 m2. 2024-JUN-25 REVISION: Change of EOR, see internal notes. |
Application Status: | ACTIVE |
Permit Value: | $28,193,544.00 |
Builder: | WESTMARK CONSTRUCTION LTD |
Issued Date: | December 22, 2023 |
Expiry Date: | December 22, 2025 |
Associated Properties
Address | Zone | More |
---|---|---|
340 CAMPBELL STREET | DT3 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PARTIAL |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PARTIAL |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PARTIAL |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.