BP129577 - 6374 Metral Drive (VIREB)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129577 - 6374 Metral Drive (VIREB) | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 6374 Metral Drive (VIREB) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP129577 |
Date Application Submitted: | September 26, 2023 |
Application Description: |
(Vancouver Island Real Estate Board VIREB) Interior renovations to the singular suite within the building, including new offices, staff kitchen, coffee room, exit and emergency lights, addition of 2 and relocation of 9 sprinkler heads. Doors and interior accessible routes to CSA B651-12. Existing Building Classification (BP042804): BCBC 1992 Group D 3.2.2.39. (BCBC 2018 3.2.2.63.), 1015 m2 building area, one storey w/ basement, facing one street, combustible and noncombustible construction, sprinklered to NFPA 13-1989, with fire alarm. 45-min FRR/FS floors, 45-min FRR for combustible (no FRR for noncombustible) loadbearing walls/columns arches. |
Application Status: | ACTIVE |
Permit Value: | $450,000.00 |
Builder: | CALJOUW CONTRACTING LTD |
Issued Date: | March 26, 2024 |
Expiry Date: | March 26, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
6374 METRAL DRIVE | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
APPROVAL-FIRE
Approval required prior to Occupancy |
APPROVED |
FINAL
Final approval as per requirements on plans. |
CANCELLED |
FINAL
Final approval as per requirements on plans. |
FAILED |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.