BP129619 - 17 Church Street (BCFNJC)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129619 - 17 Church Street (BCFNJC) | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 17 Church Street (BCFNJC) |
Type of Application: | Leasehold Improvements |
File Number: | BP129619 |
Date Application Submitted: | October 18, 2023 |
Application Description: |
(BC First Nations Justice Council). Installation of new accessible washroom on main floor, addition of accessible chair lift at side entry, interior renovations including prefabricated privacy booths (UL962 listed) with sprinklers. 2024-JUN-04 REVISION: Revise office pod locations on second floor and associated sprinkler drawings. Building Classification (BP047143): Great National Land Building (Lot E, ca. 1913). BCBC 1992 Part 9 Group D with Part 4 structural design, three storeys, 205.6 m2 building area, combustible and noncombustible construction, sprinklered, with fire alarm. 45-min FRR/FS first and third floor assemblies, elevator shaft, exit stair; 45-min FRR second floor assembly (interconnected floor space with first level, BCBC 1992 3.2.8.2.(6)). Single exit per BCBC 1992 Alternate Compliance Measure No. 19 - Table 2.1.6.A. |
Application Status: | ACTIVE |
Permit Value: | $50,000.00 |
Issued Date: | February 08, 2024 |
Expiry Date: | February 08, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
17 CHURCH STREET | DT1 | Property Report |
17 CHURCH STREET | DT1 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
CANCELLED |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.