BP129686 - 3260 Norwell Drive (Nanaimo Clinic)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129686 - 3260 Norwell Drive (Nanaimo Clinic) | |
---|---|
Neighbourhood: | Rutherford |
Street Address: | 3260 Norwell Drive (Nanaimo Clinic) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP129686 |
Date Application Submitted: | November 16, 2023 |
Application Description: |
Renovation of existing Group D occupancy building to accommodate Health Clinic. Scope of work includes the addition of a new 6' fire line service for NFPA 13 FSS sprinklers, remove all interior partion walls and relocate to create exam rooms, treatment rooms,offices and accessible washrooms. Building Classification: 2018 BCBC Part 9 Bldg, 535m2 Bldg Area, 2 storeys, Group D(personal service) & Group F3(parking), facing 2 streets, combustible construction, Sprinklered with F/A, 45 min floor assemblies required for second floor, 1.5hr FRR F/S floor assembly required between parking garage(F3) & first floor(Group D). |
Application Status: | ACTIVE |
Permit Value: | $2,310,000.00 |
Builder: | TECTONICA MANAGEMENT INC |
Issued Date: | April 09, 2024 |
Expiry Date: | April 09, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
3260 NORWELL DRIVE | COR3 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
FAILED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
MONITORING FIELD REVIEW
A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional. |
MONITORED |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.