BP130011 - 9-4890 Rutherford Road (Long Lake Dental)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP130011 - 9-4890 Rutherford Road (Long Lake Dental)
Neighbourhood: Rutherford    
Street Address: 9-4890 Rutherford Road (Long Lake Dental)
Type of Application: Commercial / Multi-Res Alteration
File Number: BP130011
Date Application Submitted: April 22, 2024
Application Description: Change of use from Group E to Group D (Long Lake Dental), 420 m2, work includes adding interior partition walls to create 17 work stations, staff lunchroom, waiting area, offices and additional WCs, extending the required fire separation to the underside of the roof deck. Changes to plumbing system includes relocating 2 toilets, 2 washbasins and installation of 1 toilet.

Existing building is 761.62 m2, ends at firewall, BCBC 2012 Group A2, 3.2.2.28. one storey, 1200 m2 facing 3 streets (doubled size permitted provided no basement and min.1 hr FS between suites), BCBC2024 Group D- 3.2.2.64. combustible const, Major occupancies in building E, D and A-2
REVISION: delete proposed sanitary pump as gravity connections available.
Application Status: ACTIVE
Permit Value: $200,000.00
Builder: KUSTOM DESIGN & BUILD
Issued Date: July 19, 2024
Expiry Date: July 19, 2026

Associated Properties

Address Zone More
4890 RUTHERFORD ROAD COR3 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
PLUMBING FINAL

All fixtures must be in place.

FAILED
FINAL

Final approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy