BP130233 - 103-1855 Boxwood Road (Hardwood Specialty Products LP)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP130233 - 103-1855 Boxwood Road (Hardwood Specialty Products LP) | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 103-1855 Boxwood Road (Hardwood Specialty Products LP) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP130233 |
Date Application Submitted: | July 09, 2024 |
Application Description: |
Create new CRU (Unit 103, 768 m2) for an F2 Occupancy with subsidiary office. Work includes construction of 37 m2 office with 37 m2 enclosed mezzanine above, construction of 45 min FRR/FS demising wall (provided by water curtain under alternative solution) plumbing work include adding 1 universal WC and 1 sink, changes to sprinkler system includes addition of 36 heads. Original Building Classification 1952 m2 warehouse building, BCBC 2018 3.2.2.79. (BCBC 2024 3.2.2.81) Group F2 occupancy, 1 storeys, sprinkled, fire alarm system, combustible or noncombustible construction. Noncombustible cladding provided. 1729 m2 pre-engineered warehouse with 223 m2 subsidiary office. Revision 2025-03-06- 45 min FRR/FS being supplied by water curtain under alternative solution. |
Application Status: | ACTIVE |
Permit Value: | $200,000.00 |
Builder: | WESTMARK CONSTRUCTION LTD |
Issued Date: | November 29, 2024 |
Expiry Date: | November 29, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
1855 BOXWOOD ROAD | I2 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.